17GB
Technical data
Rated voltage: 400 V 3 N 50 Hz AC
Schaltleistung: max 9 kW resistive load (AC 1 operation)
upgrade to 36 kW possible through connection to power
control units
Heating time shut-off: 6 h
Display: LCD, backlit
Protection type: IPx4 in accordance with DIN 40050 (German Standards
Institution), splashproofing
Control range, sauna operation: 30 to 115°C
Sensor system: KTY-Sensor with overheat shutoff protection at 139° C
Control characteristics: digital two-step control of -20° C - max. cab temperature
Fan capacity:: max. 100 W, max. 450 mA (only fan without capacitor)
Light: max. 100 W, max. 450 mA (only ohm resistive load)
Error display: blinking warning triangle and error code on LCD
Environmental temperature: 0°C to +40°C
Storage temperatures: -20°C to +70°C
Fuse protection on the light and the ventilation can
be a maximum of 1A delay action. There is a danger
of fire if greater fuse protection is used!